WGDW 시리즈 (고저온 시험상자)
고저온 시험상자
공업 조형이 독특하다. 가격대비 높은. 광범위한 응용.
Neware high and low temperature test chamber is a special equipment for battery test in new energy industry, which has independent property rights. It can provide high and low temperature simulated climate environment for battery charging and discharging test. At the same time, it is also the reliability test equipment for all kinds of electronic, electrical, plastic and other raw materials and equipments for cold resistance, heat resistance, moisture resistance, dry resistance test.
Every test chamber is customizable to fit your exact needs.
Neware Environmental Test Chambers incorporate innovative engineering and advanced technology. The quality construction, long lasting durability and Future-Proof chamber performance are unmatched in the industry.

Suitable is the best. High and Low Environmental Test Chambers .

WGDW SERIES High-Low Environmental Test Chambers (Coin cell All-in-one)

Volume: 150L/225L;
物料编码: WGDW-225L-40-mA160CH;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~85℃;
Temperature Fluctuation: ≤1℃ (no load and stable temperature);
Temperature Deviation: ±1.5℃ (no load and stable temperature);
Heating Up Time: +20℃→+85℃ ≤40 min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃ ≤60 min (No load, average nonlinearity);

MORE

WGDW SERIES High-Low Environmental Test Chambers (3C All-in-one)

Volume: 50L;
Material coding: WGDW-50L-40-5V30A16CH;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~100℃;
Temperature Fluctuation: ≤±0.5℃(no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→+100℃ ≤40 min(No load, average nonlinearity);
Cooling Time: +20℃→-40℃ ≤60 min (No load, average nonlinearity);

MORE

MGDW Series - High and Low Temperature Chambers (Standard)

Volume: 150L/225L/408L/800L/1000L;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~150℃;
-40℃~+150℃;
-70℃~+150℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);

More

MGDW Series - High and Low Temperature Chambers (Humidity)

Volume: 150L/225L/408L/800L/1000L;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~150℃;
-40℃~+150℃;
-70℃~+150℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);

More

MGDW Series - High and Low Temperature Chambers (Flameproof)

Volume: 150L/225L/408L/800L/1000L;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~150℃;
-40℃~+150℃;
-70℃~+150℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);
Functions: Explosion-proof pressure-relief port, Smog Testing and automatic (manual) smoke exhaust, etc.

More

MGDW Series - High and Low Temperature Chambers (Humidity & Flameproof)

Volume: 150L/225L/408L/800L/1000L;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~150℃;
-40℃~+150℃;
-70℃~+150℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);
Functions: Explosion-proof pressure-relief port, Smog Testing and automatic (manual) smoke exhaust, etc.

More

MGDW Series - High and Low Temperature Chambers (Automatic Fire Extinguishing & Flameproof)

Volume: 150L/225L/408L/800L/1000L;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~150℃;
-40℃~+150℃;
-70℃~+150℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);
Functions: Explosion-proof Pressure-relief Port, Smog Testing, Automatic (Manual) Smoke Exhaust and Carbon Dioxide (CO2) Automatic (Manual) Spray, etc.;

More

MGDW Series - High and Low Temperature Chambers (Automatic Fire Extinguishing, Flameproof & Humidity)

Volume: 150L/225L/408L/800L/1000L;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~150℃;
-40℃~+150℃;
-70℃~+150℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);
Functions: Explosion-proof Pressure-relief Port, Smog Testing, Automatic (Manual) Smoke Exhaust and Carbon Dioxide (CO2) Automatic (Manual) Spray, etc.;

More

MGDW Series - High and Low Temperature Chambers (Double layer standard)

Volume: 150L/225L;
Test Method: GB/T 5170.2-2017;
Temperature Range: 20℃~150℃; -40℃~150℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);

More

MGDW Series - High and Low Temperature Chambers (Double layer Flameproof)

Volume: 150L/225L;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~150℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);
Functions: Explosion-proof pressure-relief port, Smog Testing and automatic (manual) smoke exhaust, etc.

More

MGDW Series - High and Low Temperature Chambers (Double layer Automatic Fire Extinguishing & Flameproof)

Volume: 150L/225L;
Test Method: GB/T 5170.2-2017;
Temperature Range: -40℃~150℃;
Temperature Fluctuation: ≤±0.5℃ (no load and stable temperature);
Temperature Deviation: ±2.0℃ (no load and stable temperature);
Heating Up Time: +20℃→±150℃≤60min (No load, average nonlinearity);
Cooling Time: +20℃→-40℃≤60min (No load, average nonlinearity);
Functions: Explosion-proof Pressure-relief Port, Smog Testing, Automatic (Manual) Smoke Exhaust and Carbon Dioxide (CO2) Automatic (Manual) Spray, etc.;

More